More Information

Enclosure 9 DIN (162 mm)
Measuring current 100 A / determined by current transformer
Max. switching current 8 A / determined by contactor A
Max. measuring power 30 kW / determined by current transformers
Number of phases 3
Installation method Into a panel (DIN rail)
Brand Novatek
Rated operating voltage 230/400 AC (phase/line voltage)
Controlled parameters Voltage, Current, Power
Additional features Timer, On/off protection, Voltage protection, PC software, Modbus protocol support
Operating method Buttons, Modbus protocol
Indication Display
Available delivery methods: Pickup from the store, Nova Poshta.
Payment methods: Bank transfer, Cash on delivery.

Detail product Description

The OM-310 power limiter is designed for:

  • protecting the consumer in the event of poor electrical network parameters.
  • completely disconnecting the load if the consumed power exceeds the primary threshold for a user-specified time.
  • partially disconnecting the load if the consumed power exceeds the secondary threshold for a user-specified time.
  • measuring and displaying the parameters of a three-phase electrical network (current values of phase and line voltages; voltages of direct, reverse, and zero sequences; current values of phase currents; active, reactive, and total power consumed by the load, and power factor cos φ).
  • alerting about emergency situations.
  • remotely connecting and disconnecting the load via the RS-232 / RS485 interface or an external switch.

The device supports operation with loads ranging from 2.5 kW to 30 kW when using built-in current transformers, and up to 350 kW when using external current transformers, including networks with an isolated neutral.

The OM-310 provides the following types of consumer protections:

  • in case of poor network voltage quality (unacceptable voltage surges, phase breaks, phase sequence violations, phase interlocking, phase/line voltage imbalances).
  • when the maximum set current per phase of the load is exceeded.
  • for leakage currents to "ground".
  • For each type of protection, it is possible to enable or disable automatic load reconnection.

Protection of electrical equipment is ensured by controlling the coil of a magnetic starter (contactor).

Novatek-electro